Call the mode to enter a correction value, Begin entering a value, Enter the value – Rice Lake TA Series, Rice Lake Weighing Systems User Manual

Page 33: Save the value, Entering water temperature or the, Specific gravity of the media

Advertising
background image

RL-TA Series Operation Manual 29

11.2 Entering water temperature or the specific gravity of the media

This is for entering correction data for the liquid media to be used for the measurement. Enter water

temperature if the media is water. Otherwise, enter the specific gravity value of the liquid. Use Function

1 [

11.NEd. *] for selecting the media as follows:

1.

Call the mode to enter a correction value.
Press and hold the Zero/Tare key to enter the temperature

setting mode and then enter the water temperature (for any

media other than water, enter the specific gravity value of

the media).

If the media is water, [

dt] is displayed on the right side of

the display. Otherwise, [

d

] will be indicated instead.

2.

Begin entering a value.
Press the Zero/Tare key.

The [

0] indication blinks.

3.

Enter the value.
Change the value using the Zero/Tare key. Pressing the

key changes the value as shown on the right.


Press the Function key to enter a higher-order digit.

4.

Save the value.
Upon completing the entry, press the Target key to return to

the weight display mode.

The acceptable range of numeric entry is specified as follows:

Media

Input Data

Range

Water

Water temperature

0.0 to 99.9

°C

Any liquid other than water

Specific gravity

0.0001 to 9.9999

If any value outside the above specified range is entered, either the minimum or the maximum value within

the range will be set.

The value set is held even after the power is turned off.