Cub Cadet SLTX1000 Series User Manual

Page 194

Advertising
background image

LTX Tractors

188

6.

Starting with a fully charged battery and battery
cable connections that are clean and tight, measure
the battery voltage. See Figure 7.59.

7.

With the circuit energized, start at either end of the
circuit and check for voltage.

If starting at the battery end of a powered cir-
cuit, trace it through until power vanishes.

If starting at the ground end of a powered cir-
cuit, trace it through to the point that power
appears.

If there is low voltage at the far end of the cir-
cuit, do a voltage drop test (as described later
in this section) on the circuit to find the source
of resistance.

NOTE: When working toward the battery, check each junction with the connector disconnected, then re-check

it with the junction reconnected. If there is voltage with the connector unplugged but not when it is con-
nected there is a short between that point and the last connector tested.

NOTE: When working toward the battery, if one junction has lost power, but the next connector has voltage

with its junction still connected, there is an open between the two junctions.

8.

Continue checking each connector until the other end of the circuit is reached or the fault is found.

Figure 7.59

Advertising