GLOSSARY OF TERMS

Axial Piston: Type of design for hydraulic motors and pumps in which the pistons are arranged
parallel with the spindle (input or output shaft).

Bantam Duty:

A descriptive term relating to the product capacity (meaning: light duty).


Bypass Valve:
A valve whose primary function is to open a path for the fluid to bypass the motor
or pump. Also referred to occasionally as the freewheel valve or dump valve.

Case Drain Line (Return Line):
A line returning fluid from the component housing to the
reservoir.

Cavitation:

A concentrated gaseous condition within the fluid causing the rapid implosion of a

gaseous bubble.

Center Section:
A device which acts as the valve body and manifold of the transmission.

Charge Pump:
A device which supplies replenishing fluid to the fluid power system (closed loop).

Charge Pressure:

The pressure at which replenishing fluid is forced into a fluid power system.


Charge Relief Valve:

A pressure control valve whose primary function is to limit pressure in the

charge circuit.


Check Valve:
A valve whose primary function is to restrict flow in one direction.

Closed Loop:
A sealed and uninterrupted circulating path for fluid flow from the pump to the motor
and back.

Decay Rate:
The ratio of pressure decay over time.

End Cap:
See “Center Section”

Entrained Air:
A mechanical mixture of air bubbles having a tendency to separate from the liquid
phase.

Gerotor:
A positive displacement pump frequently used as a charge pump.

Hydraulic Motor:

A device which converts hydraulic fluid power into mechanical force and motion

by transfer of flow under pressure.

Hydraulic Pump:
A device which converts mechanical force and motion into hydraulic fluid power
by producing flow.

Hydrostatic Pump:

See “Hydraulic Pump”