Troubleshooting 145

The screen shows the individual load sensors in dwell mode. Using the right+ left button,
move from Sensor to Sensor. The pass/fail test requires 15-30 seconds to complete testing.

IT Dwell – Jbox1

Channel x (x/5)

RAW

Waversaver

Results

OK

OK

Variation 0.45

0.00

mV/V

0.0219

Weight

-0.378605

RTZ

PASS