Graduation size parameter – Hardy HI 6300 Series User Manual

Page 92

Advertising
background image

84 Chapter

5

RANGE: 0-5 (default 2) Not to exceed 1 part in 100,000

On the Web page, from the Decimal Point pull-down list, select the decimal position for
this instrument.

On the HI 6300 series instrument display, select the Setup menu and use the UP or
DOWN button to select the Decimal Point menu item. The list of decimal point values
supported will be displayed and the current value will be highlighted, if the decimal point
needs to be modified use the UP and DOWN buttons to select a new value and press the
ENTER button.

Graduation Size Parameter

The Graduation Size is the Minimum increment displayed by the instrument. The Base
Graduation Number can be calculated by dividing the Total Load Cell Capacity by 10,000.

For example, with two decimal points selected, a graduation size of 10 will display
increments of .10 units and the graduation size .50 will display increments of.50 units. For
a scale with 10,000 capacity, graduation size = 1

RANGE: 1, 2, 5,10, 20, 50, 10, 200, 500, 1000 (default 1)

On the Web page, from the Grads pull-down menu, select a Graduation Size Parameter for
this instrument.