Communications parameters for the hi 6310 only, Printer (over rs-232), Usb memory stick – Hardy HI 6300 Series User Manual

Page 45: Printer (over rs-232) usb memory stick

Advertising
background image

Network Configuration 37

Communications Parameters for the HI 6310 Only

Printer (over RS-232)

Available on the HI 6310 only.

The HI 6310 can transmit Gross, Net, Count, Tare values to a serial printer over RS-232.
The printer Baud rate is user selectable at 600, 1200, 2400, 4800, 9600, or 19200 (default
is 9600).

A sample wiring connection from the HI 6310 to the printer port is shown above. The
printer parameters can be configured through the web interface or the display panel.

Step 1. Set the baud rate for the RS232 printer, default is 9600.

Step 2. Set the parity bit, default is EVEN

Step 3. Select what values to transmit over the serial interface to the printer using the

printer mode, default is disabled.

a. Gross Weight
b. Net Weight
c. Tare Weight
d. Unit Count
e. All – Gross, Net, Tare, and Count (if Count enabled) values
f. OFF, Printer disabled.

USB Memory Stick

Available on the HI 6310 only.

The HI 6310 provides an interface to an external USB memory stick that allows HI 6310
parameters to be saved, restored. or copied to another instrument.

The USB memory stick commands can be activated through the web interface or the
display panel.

To access the USB Menu, from the front keypad, select Configuration > Enter,
Communications > Enter, USB >Enter, UP or DOWN arrow to Save or Restore > Enter.

On the Web page: Configuration; communications; USB; save/restore.

Advertising