Super Systems 9120 with TS User Manual

Page 21

Advertising
background image

SSi 9120 Touchscreen Interface

4586 – 9120 With Touch Screen Interface

Page 21 of 80

This value is the supervisor-level passcode for any web-based operations with the 9120
controller. Clicking on the value will allow the operator to change the value. The range for the
passcode is -32767 to 32767.

Web Level 2 Code
This value is the administrator-level passcode for any web-based operations with the 9120
controller. Clicking on the value will allow the operator to change the value. The range for the
passcode is -32767 to 32767.

Web Change Enable
This will either enable or disable the web change feature, which will allow changes to be made
over the web page for the 9120 controller. Clicking on the value will allow the operator to change
the value. Select either a 0 (Web Change Disable) or a 1 (Web Change Enable).

O2 Mode
This value will allow the operator to select the oxygen mode.
Clicking on the value will allow the operator to change the value.
The options are:
% with control
Monitor
Offset log with control


Sample Pump Mode
This menu option will allow the user to turn the sample pump On or Off. For the HP PVT types
(% Carbon, Dewpoint, Oxygen, Millivolt, and Redundant Probe), there is the option to set
a minimum temperature in order for the pump to run. See the “Minimum Temp/Pump Run”
description below.

Minimum temp/pump run
This option will set the minimum temperature for the pump to run, if that feature is used. A 0
value will disable the minimum temperature feature.

Note - The furnace that is being sampled

must have its temperature connected to input 3 for the pump minimum temperature feature to
work

. The range is 0 to 32767.


Remote Setpoint
This option will allow the user to select where the remote setpoint will come from. The options
are:
None
Slave 1 PV
Slave 2 PV
Slave 1 SP
Slave 2 SP
Input 3

Remote Setpoint Hysteresis
This option will allow the user to enter the remote setpoint hysteresis. The range is 0 to 32767.

Loop 2 PV source

Advertising
This manual is related to the following products: