SSi 9120 Touchscreen Interface

4586 – 9120 With Touch Screen Interface

Page 46 of 80

Aux Analog Inputs

This menu option shows the
process variables for the 3 analog
inputs of the 9200 dual loop
controller. It also shows the
input types and any information
from attached slave analog input
modules.

Note – None of these

values can be modified on this
screen

.











Burnoff Setup

This menu option allows the user to
modify the settings that are associated
with the probe burnoff (menu option

Burnoff

).

Burnoff Time
The amount of time from the beginning
of the burnoff to the end of the burnoff
measured in seconds. Clicking on the
value will allow the user to change the
value.

Burnoff Recovery Wait Time
The amount of time allotted to allow the
probe measurements to return to a stable, accurate range after the burnoff is complete. This is
measured in seconds. The control output is held until this time is elapsed. Clicking on the value
will allow the user to change the value.

Burnoff Interval
The amount of time between the beginning of one burnoff and the beginning of the next
scheduled burnoff measured in minutes. Clicking on the value will allow the user to change the
value.

Burnoff Minimum Millivolts