SSi 9120 Touchscreen Interface

4586 – 9120 With Touch Screen Interface

Page 58 of 80


O2 Exponent Range
This will set the exponent range for Oxygen. The range is 010.

Relay Assignments
Relay 1 – Relay 8
This value will display what the relay is
assigned as. The value cannot be changed
from this menu option.

Note – Only some of the relay assignments
can be modified depending on the PVT
type

.


This screen will display a description of the
eight relay assignments. Most of the relay
assignments are fixed in the unit. Relay 1
is the loop 2 control relay. Relay 2 is the
input 2 high limit relay. Relay 3 is the loop
1 increase relay. Relay 4 is the loop 1
decrease relay. Relay 6 is the probe burnoff relay. Relay 8 is the any alarm relay. Relay 7 is the
only relay that can be assigned. If the assignment can be modified, the user will have following
options:
Loop 1 Fwd

Event 3

Burnoff

Loop 1 Rev

Event 4

IN1 Relay SP A

Loop 2 Fwd

Event 5

IN1 Relay SP B

Loop 2 Rev

Event 6

IN1 Relay SP C

Loop 3 Fwd

Event 7

IN2 Relay SP A

Loop 3 Rev

Event 8

IN2 Relay SP B

Programmer Alarm

Event 9

IN2 Relay SP C

Alarm 1

Event 10

IN3 Relay SP A

Alarm 2

Event 11

IN3 Relay SP B

Alarm 3

Event 12

IN3 Relay SP C

Event 0

Event 13

Alarm Combination

Event 1

Event 14

N/A

Event 2

Event 15


The Alarm Combination option will enable the
checkboxes on the screen for selection. Any or all
of the options can be selected: Programmer
Alarm
, Alarm 1, Alarm 2, Alarm 3, or T/C
Check
.