WAVECOM Decoder W61PC/LAN Manual V7.5

BIIS

Binary Interchange of Information and Signaling is an ETSI-standard (ETS 300 230) used for transmission
of signaling information for selective calls, status messages, short text messages and data.

Parameter

Value

Frequency range

VHF/UHF

Operation modes

CRC and parity

Modulation

FM, SUB FFSK

Symbol rate

1200 Baud

Center frequency

1500 Hz

Shift

600 Hz

Receiver settings

FM, BW = 15 kHz

Input format(s)

AF, IF

Additional Info

Signaling data, Short Data transfer, HDLC possible, ETSI-standard (ETS 300

230)

The system operates at 1200 Bit/s using indirect FSK modulation in the VHF or UHF band. To accommo-
date the different types of data, a number of code words have been defined. Every transmission consists
of at least one address word. Additional data such as telephone numbers or short text messages may be
appended to the address word as one or more data blocks.

For the transmission of longer data packets the High-Level Data Link Control (HDLC) protocol may be im-
plemented in the BIIS devices.

Status messages are transmitted within the address word. The address word contains the Operational
Mode Characteristic (OMC), a regional code indicating the country of the device, a common address part,
the transmitter address and the receiver address. The address data is displayed in hexadecimal format.
OMC code and regional code are displayed as short strings. There are 64 OMC codes consisting of a cate-
gory part (CAT) and a function part (FNC). Some codes are custom, status or reserved codes. The follow-