Analysis Tools

79

Steps:

After starting the FSK code check, the frequency shift, center frequency and the baud rate are de-

termined. The values of these parameters are displayed in the appropriate fields after the meas-
urement has completed.

The software then proceeds with code and system analysis. The incoming bit stream is tested and

compared against known modes.

The name of each identified system is displayed in the output window. An identified system may

be immediately started by double-clicking the system in the output window - for instance double-
clicking ACARS in the figure above will interrupt FSK code checking and immediately start ACARS.

The Hits-Checks will show you how often during checking a mode was successfully determined. If

multiple modes are listed this will indicate which mode should be tried.

If a mode is uniquely identified, the software will switch to the identified mode and decoding is ini-

tiated with the measured values of mode, baud rate, shift, and center frequency.

If two or more different systems are identified or if too many transmission errors occur, an auto-

matic switch to a mode will not take place.

Noise Gate Mode…

The Noise Gate Mode can be selected by Options | Noise Gate Mode… or by double-clicking the Noise
Gate Mode
field in the Status Bar.

In Enabled mode, a Noise Gate is used. This is necessary as this kind of signal is not continuous.

The noise gate examines the input signal and determines if a valid signal is available which can be
analyzed, or if the input consists only of noise .

In Disabled mode the Noise gate is switched off.