# Display zone set information for VSAN 1.

<SwitchB> display zoneset vsan 1

VSAN 1:

zoneset name Zoneset1

zone name Zone1

fcid 0x010001

zone name Zone2

fcid 0x010002 initiator

pwwn 11:22:33:44:55:66:77:88 target

zone-alias Alias1

fcid 0x020004 target

pwwn 22:33:44:55:66:77:88:99 target

zone name Zone3

fcid 0x010003 initiator

zone-alias Alias1

fcid 0x020004 target

pwwn 22:33:44:55:66:77:88:99 target

# Display information about Zone 2 in VSAN 1.

<SwitchB> display zone name Zone2 vsan 1

VSAN 1:

zone name Zone2

fcid 0x010002 initiator

pwwn 11:22:33:44:55:66:77:88 target

zone-alias Alias1

fcid 0x020004 target

pwwn 22:33:44:55:66:77:88:99 target

# Display information about all zone aliases.

<SwitchB> display zone-alias

VSAN 1:

zone-alias name Alias1

fcid 0x020004 target

pwwn 22:33:44:55:66:77:88:99 target

# Display the zone or zone alias to which 020004 (FC ID type) belongs.

<SwitchB> display zone member fcid 020004

fcid 0x020004

VSAN 1:

zone-alias Alias1

zone Zone2

zone Zone3

# Display information about the active zone set in VSAN 1.

<SwitchB> display zoneset active vsan 1

VSAN 1:

zoneset name Zoneset1