Verifying the configuration – H3C Technologies H3C S10500 Series Switches User Manual

Page 140

Advertising
background image

129

[SwitchA] fcping fcid fffc03 vsan 1

FCPING fcid 0xfffc03: 128 data bytes, press CTRL_C to break.

Request time out

Request time out

Request time out

Request time out

Request time out

--- 0xfffc03 fcping statistics ---

5 packet(s) transmitted

0 packet(s) received

100.00% packet loss

The output shows that Switch A cannot reach Switch C.

5.

Use the fctracert command to identify the faulty node.

[SwitchA] fctracert fcid fffc03 vsan 1

Route present for: 0xfffc03, press CTRL_C to break

20:00:00:0b:46:00:02:82(0xfffc01)

20:00:00:05:30:00:18:db(0xfffc02)

Fctracert uncompleted: no route to destination port.

The output shows that:

{

Switch A can reach Switch B.

{

Switch B cannot reach Switch C.

Verifying the configuration

# Use the display fc routing-table command on Switch B to verify that there is not a route to Switch C.

(Details not shown.)

Advertising