Configuration guidelines, Configuration procedure – H3C Technologies H3C S10500 Series Switches User Manual

Page 30

Advertising
background image

19

keepalive frame, the switch maintains the status of the virtual link. If the switch fails to receive a keepalive

frame within 2.5 FKA advertisement intervals, it deletes the virtual link.

Configuration guidelines

When setting the FKA advertisement interval value on an FCF or NPV switch, use

Table 2

as a reference

to avoid service disruption.

Table 2 Recommended values for different application scenarios

Recommended

value

Application scenarios

Remarks

Less than 90
seconds

Connected to servers, storage
devices, or third-party switches.

According to FC-BB-5, the upper limit of the FKA
advertisement interval is 90 seconds. In this scenario, a

single-MPU FCF switch or NPV switch will experience
FCoE traffic disruption during an ISSU reboot because

of the following reasons:

This ISSU reboot takes more than 225 (2.5*90)

seconds.

The peer deletes the virtual link for failing to receive

unsolicited Discovery Advertisements within 225
seconds.

You must also adjust the FKA advertisement interval on
the upstream FCF switch to ensure service continuity in

the following cases:

An active/standby switchover on an NPV switch.

An ISSU reboot on a dual-MPU NPV switch.

You must do that for the following reasons:

The FKA advertisement interval set on the NPV switch

affects only its VFC interfaces in F mode and

connected ENodes.

Its VFC interfaces in NP mode use the FKA

advertisement interval learned from the upstream

FCF switch.

60–90 seconds

Active/standby switchover on
the switch takes more than 2.5 x

60 seconds because of the
amount of FCoE configuration.
ISSU reboot on a dual-MPU
switch takes more than 2.5 x 60

seconds because of the amount
of FCoE configuration.

For more information about ISSU, see Fundamentals
Configuration Guide
.

300–600
seconds

ISSU reboot on a single-MPU
switch to which no nodes are

attached.

During an ISSU reboot on a single-MPU switch, the
switch cannot send unsolicited Discovery

Advertisements or keepalive frames.

Configuration procedure

To set an FKA advertisement interval value:

Advertising