Verifying the configuration – H3C Technologies H3C S10500 Series Switches User Manual

Page 59

Advertising
background image

48

[SwitchB] vsan 1

[SwitchB-vsan1] zone default-zone permit

[SwitchB-vsan1] quit

Verifying the configuration

# Verify the configuration on Switch A.

[SwitchA-vsan1] display fc domain vsan 1

Domain Information of VSAN 1:

Running time information:

State: Stable

Switch WWN: 48:33:43:2d:46:43:1A:1A

Fabric name: 11:11:11:11:11:11:11:11

Priority: 128

Domain ID: 1

Configuration information:

Domain configure: Disabled

Domain auto-reconfigure: Disabled

Fabric name: 11:11:11:11:11:11:11:11

Priority: 128

Domain ID: 1 (static)

Principal switch running time information:

Priority: 128

No interfaces available.

The output shows that the domain configuration is complete and that the runtime domain ID of Switch A
is 1.
# Verify the configuration on Switch B.

[SwitchB-vsan1] display fc domain vsan 1

Domain Information of VSAN 1:

Running time information:

State: Stable

Switch WWN: 48:33:43:2d:46:43:1B:1B

Fabric name: 11:11:11:11:11:11:11:11

Priority: 128

Domain ID: 2

Configuration information:

Domain configure: Disabled

Domain auto-reconfigure: Disabled

Fabric name: 11:11:11:11:11:11:11:11

Priority: 128

Domain ID: 2 (static)

Principal switch running time information:

Priority: 128

No interfaces available.

Advertising