H3C Technologies H3C S10500 Series Switches User Manual

Page 138

Advertising
background image

127

system to make it effective.

[SwitchB] save

[SwitchB] quit

<SwitchB> reboot

# Configure the switch to operate in FCF mode.

<SwitchB> system-view

[SwitchB] fcoe-mode fcf

# Enable the fabric configuration feature for VSAN 1.

[SwitchB] vsan 1

[SwitchB-vsan1] domain configure enable

# Set the domain ID to 2.

[SwitchB-vsan1] domain-id 2 static

# Disable FSPF for VSAN 1.

[SwitchB-vsan1] undo fspf enable

# Configure a static route.

[SwitchB-vsan1] fc route-static 010000 8 vfc 1

[SwitchB-vsan1] quit

# Create interface VFC 1.

[SwitchB] interface vfc 1

# Configure the mode of VFC 1 as E.

[SwitchB-Vfc1] fc mode e

# Bind VFC 1 to interface Ten-GigabitEthernet 1/0/1.

[SwitchB-Vfc1] bind interface ten-gigabitethernet 1/0/1

# Assign VFC 1 to VSAN 1 as a trunk port.

[SwitchB-Vfc1] port trunk vsan 1

[SwitchB-Vfc1] quit

# Configure Ten-GigabitEthernet 1/0/1 as a trunk port, and assign the port to VLAN 10.

[SwitchB] interface ten-gigabitethernet 1/0/1

[SwitchB-Ten-GigabitEthernet1/0/1] port link-type trunk

[SwitchB-Ten-GigabitEthernet1/0/1] port trunk permit vlan 10

[SwitchB-Ten-GigabitEthernet1/0/1] quit

# Create interface VFC 2.

[SwitchB] interface vfc 2

# Configure the mode of VFC 2 as E.

[SwitchB-Vfc2] fc mode e

# Bind VFC 2 to interface Ten-GigabitEthernet 1/0/2.

[SwitchB-Vfc2] bind interface ten-gigabitethernet 1/0/2

# Assign VFC 2 to VSAN 1 as a trunk port.

[SwitchB-Vfc2] port trunk vsan 1

[SwitchB-Vfc2] quit

# Configure Ten-GigabitEthernet 1/0/2 as a trunk port, and assign the port to VLAN 10.

[SwitchB] interface ten-gigabitethernet 1/0/2

[SwitchB-Ten-GigabitEthernet1/0/2] port link-type trunk

[SwitchB-Ten-GigabitEthernet1/0/2] port trunk permit vlan 10

[SwitchB-Ten-GigabitEthernet1/0/2] quit

Advertising