Interface NbrDomain IfIndex NbrIfIndex Dead Time State

Vfc1 2 0x68 0x68 00:01:06 Full

# Display the routing table information for Switch A.

[SwitchA] display fc routing-table vsan 2

Routing Table: VSAN 2

Destinations : 5 Routes : 5

Destination/mask Protocol Preference Cost Interface

0x020000/8 FSPF 20 100 Vfc1

0xfffc01/24 DIRECT 0 0 InLoop0

0xfffffa/24 DIRECT 0 0 InLoop0

0xfffffc/24 DIRECT 0 0 InLoop0

0xfffffd/24 DIRECT 0 0 InLoop0

# FCping Switch B from Switch A.

[SwitchA] fcping fcid fffc02 vsan 2

FCPING fcid 0xfffc02: 128 data bytes, press CTRL_C to break.

Reply from 0xfffc02: bytes = 128 time = 1.102 ms

Reply from 0xfffc02: bytes = 128 time = 0.276 ms

Reply from 0xfffc02: bytes = 128 time = 0.253 ms

Reply from 0xfffc02: bytes = 128 time = 0.270 ms

Reply from 0xfffc02: bytes = 128 time = 0.247 ms

--- 0xfffc02 fcping statistics ---

5 packet(s) transmitted

5 packet(s) received

0.00% packet loss

round-trip min/avg/max = 0.247/0.430/1.102 ms

The output shows that Switch A can reach Switch B.