Configuration information:

Domain configure: Enabled

Domain auto-reconfigure: Disabled

Fabric name: 48:33:43:2d:46:43:1A:1A

Priority: 128

Domain ID: 11 (preferred)

Principal switch running time information:

Priority: 1

Path Interface

Upstream Vfc1

Downstream Vfc2

The output shows that the domain configuration is complete and that the principal switch assigns domain
ID 11 to Switch A.
# Display the domain ID list of VSAN 1.

[SwitchA-vsan1] display fc domain-list vsan 1

Domain list of VSAN 1:

Number of domains: 4

Domain ID WWN

0x01(1) 48:33:43:2d:46:43:1B:1B [Principal]

0x0b(11) 48:33:43:2d:46:43:1A:1A [Local]

0x0d(13) 48:33:43:2d:46:43:1C:1C

0x0e(14) 48:33:43:2d:46:43:1D:1D

The output shows that Switch B becomes the principal switch and assigns the smallest domain ID 1 to