Verifying the configuration – H3C Technologies H3C S10500 Series Switches User Manual

Page 78

Advertising
background image

67

[SwitchC] vsan 1

[SwitchC-vsan1] domain configure enable

# Set the domain ID to 3.

[SwitchC-vsan1] domain-id 3 static

[SwitchC-vsan1] quit

# Create interface VFC 2.

[SwitchC] interface vfc 2

# Configure the mode of VFC 2 as E.

[SwitchC-Vfc2] fc mode e

# Bind VFC 2 to interface Ten-GigabitEthernet 1/0/2.

[SwitchC-Vfc2] bind interface ten-gigabitethernet 1/0/2

# Assign VFC 2 to VSAN 1 as a trunk port.

[SwitchC-Vfc2] port trunk vsan 1

[SwitchC-Vfc2] quit

# Configure Ten-GigabitEthernet 1/0/2 as a trunk port, and assign the port to VLAN 10.

[SwitchC] interface ten-gigabitethernet 1/0/2

[SwitchC-Ten-GigabitEthernet1/0/2] port link-type trunk

[SwitchC-Ten-GigabitEthernet1/0/2] port trunk permit vlan 10

[SwitchC-Ten-GigabitEthernet1/0/2] quit

# Enable FCoE for VLAN 10 and map VLAN 10 to VSAN 1.

[SwitchC] vlan 10

[SwitchC-vlan10] fcoe enable vsan 1

[SwitchC-vlan10] quit

# Configure two static routes on Switch C.

[SwitchC] vsan 1

[SwitchC-vsan1] fc route-static 010000 8 vfc 2

[SwitchC-vsan1] fc route-static 020000 8 vfc 2

Verifying the configuration

# Display the FC routing table in VSAN 1 on Switch A.

[SwitchA-vsan1] display fc routing-table vsan 1

Routing Table: VSAN 1

Destinations : 6 Routes : 6

Destination/mask Protocol Preference Cost Interface

0x020000/8 STATIC 10 0 Vfc1

0x030000/8 STATIC 10 0 Vfc1

0xfffc01/24 DIRECT 0 0 InLoop0

0xfffffa/24 DIRECT 0 0 InLoop0

0xfffffc/24 DIRECT 0 0 InLoop0

0xfffffd/24 DIRECT 0 0 InLoop0

# Display the FC routing table in VSAN 1 on Switch B.

[SwitchB-vsan1] display fc routing-table vsan 1

Routing Table: VSAN 1

Destinations : 6 Routes : 6

Destination/mask Protocol Preference Cost Interface

0x010000/8 STATIC 10 0 Vfc1

Advertising