The output shows that the domain configuration is complete on Switch A, and the principal

switch assigns domain ID 2 to Switch A.

# Display the domain ID list of VSAN 100.

[SwitchA] display fc domain-list vsan 100

Domain list of VSAN 100:

Number of domains: 2

Domain ID WWN

0x01(1) 48:33:43:2d:46:43:1C:1C [Principal]

0x02(2) 48:33:43:2d:46:43:1A:1A [Local]

The output shows that Switch C is elected as the principal switch, and the principal switch assigns domain
ID 1 to itself.
# Display the routing table information for Switch A.

[SwitchA] display fc routing-table vsan 100

Routing Table: VSAN 100

Destinations : 5 Routes : 5

Destination/mask Protocol Preference Cost Interface

0x010000/8 FSPF 20 100 Vfc10

0xfffc01/24 DIRECT 0 0 InLoop0

0xfffffa/24 DIRECT 0 0 InLoop0

0xfffffc/24 DIRECT 0 0 InLoop0

0xfffffd/24 DIRECT 0 0 InLoop0

The output shows that an FSPF route from Switch A to Switch C exists, with the outgoing interface VFC 10.
# Display the node login information for VSAN 100.

[SwitchA] display fc login vsan 100

Interface VSAN FCID Node WWN Port WWN

Vfc1 100 0x020000 21:01:00:1b:32:a0:fa:12 21:01:00:1b:32:a0:fa:11

# Display the brief information about the name server database in VSAN 100.

[SwitchA] display fc name-service database vsan 100

VSAN 100:

FCID Type PWWN(vendor) FC4-type:feature

0x010000 0x01(N) 10:00:00:05:30:00:25:a3 SCSI-FCP:Target

0x020000 0x01(N) 21:01:00:1b:32:a0:fa:11 SCSI-FCP:Initiator

Verifying the configuration on Switch C and Switch D

Verify the configuration on Switch C and Switch D, for example, Switch D.
# Display the node login information for VSAN 100.

[SwitchC] display fc login vsan 100

Interface VSAN FCID Node WWN Port WWN

Vfc1 100 0x010000 10:00:00:05:30:00:25:a4 10:00:00:05:30:00:25:a3