41

Manually initiating the fabric reconfiguration

Step Command

1.

Enter system view.

system-view

2.

Enter VSAN view.

vsan vsan-id

3.

Initiate the fabric reconfiguration.

domain restart [ disruptive ]

Configuring a VFC interface to reject incoming RCF

requests

In a stable fabric, to avoid unnecessary disruptive reconfigurations, you can configure a VFC interface to

reject RCF requests received in a VSAN. With this feature, the switch replies with a reject message and

isolates the interface that receives the RCF request.
To configure a VFC interface to reject received RCF requests:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enter VFC interface view. interface vfc interface-number

N/A

3.

Configure the VFC
interface to reject the RCF

requests received in a

VSAN.

fc domain rcf-reject vsan vsan-id

By default, a VFC interface does
not reject received RCF requests.

Enabling SNMP notifications

After you enable SNMP notifications for the fabric module or name service module, that module

generates notifications for important events and sends the notifications to the SNMP module. For more

information about SNMP notifications, see Network Management and Monitoring Configuration Guide.
To enable SNMP notifications:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enable SNMP

notifications for the fabric
module.

snmp-agent trap enable fc-fabric
[ domain-id-change | fabric-change ] *

By default, SNMP notifications are
disabled for the fabric module.

3.

Enable SNMP
notifications for the name

service module.

snmp-agent trap enable
fc-name-service [ login | logout ] *

By default, SNMP notifications are
disabled for the name service

module.