5

FC zone

The VSAN technique divides one physical SAN into multiple logical SANs. A VSAN, however, cannot

perform access control over the servers and disk devices (or the N_Ports) connected to a fabric. N_Ports

in the same VSAN can access one another only if these N_Ports register name services. This creates data
security risks.
Zoning can solve the preceding problem by dividing a VSAN into zones and adding N_Ports to different

zones for different purposes. N_Ports in different zones are separated to implement access control.
For more information about FC zones, see "

Configuring FC zones

."

FCoE

A data center using the FC SAN technology typically includes separate local area networks (LANs) and

SANs. LANs carry traditional Ethernet/IP services, and SANs carry network storage services.
To provide services for LANs and use SANs for storage simultaneously in a traditional network, the
servers must use independent Ethernet adapters and FC adapters. In addition, the IP switches and the FC

switches are also independent and have independent network connections. Such a network needs many

switches, network adapters, and cables, and it brings high investments and maintenance costs and low

scalability.
FCoE was introduced to solve this problem. FCoE transports FC over Ethernet. In an FCoE solution:

The server uses an FCoE-capable Ethernet adapter.

The FCoE forwarder (FCF) switch integrates the functions of both the traditional IP switch and FC
switch.

FCoE reduces the number of network adapters, switches, and cables, and the network operation and

maintenance workload. In all, FCoE reduces the total cost.

Figure 5 FCoE for I/O consolidation

As shown in

Figure 5

:

In the traditional network, the server is connected to the LAN through an Ethernet interface and to
the SAN through an FC interface.

LAN

SAN

LAN

SAN

Traditional network

Ethernet switch

Ethernet switch

FC switch

Ethernet switch

FCF switch

FC switch

FCF switch

Server

Server

I/O consolidation with FCoE

Ethernet
FC

FCoE