Configuring NPV

Overview

NPV enables an FC SAN to accommodate more than 239 switches.
NPV switches forward traffic from nodes to the core switch.

Figure 28

shows a typical NPV network diagram.

Figure 28 NPV network diagram

NOTE:

An NPV switch must be directly connected to the core switch.

Downlink interface and downlink

A downlink interface, also known as a server interface, is an interface through which an NPV switch

connects to a node. It must be a VFC interface operating in F mode.
A downlink is a link from an NPV switch to its node.
Each downlink interface is uniquely mapped to an operational uplink interface. All traffic from the node

connected to the downlink interface is forwarded to the core switch through the uplink interface.

Uplink interface and uplink

An uplink interface, also known as an external interface, is the interface through which an NPV switch

connects to the core switch. It must be a VFC interface operating in NP mode.
An uplink is a link from an NPV switch to the core switch.
When the uplink becomes operational, the NPV switch sends a fabric login (FLOGI) packet to the core

switch for registration. The core switch assigns the uplink interface (NP_Port) an FC address. Then, the

NPV switch registers itself with the name server on the core switch. When receiving a packet from a node,

the NPV switch performs the following operations:

Forwards the packet to the core switch through the mapped uplink interface.