Configuration for 12 or 24 vdc power option – Precision Digital PD6200 User Manual

Page 18

Advertising
background image

Model PD6200 Analog Input Rate/Totalizer

Instruction Manual

18

Configuration for 12 or 24 VDC Power Option

Warning!

Do not exceed voltage rating of the selected
configuration.

Meters equipped with the 12/24 VDC power option are shipped from
the factory ready to operate from 24 VDC.
To configure the meter for 12 VDC power:

1. Remove all the connectors.
2. Unscrew the back cover.
3. Slide the back cover about 1 inch.
4. Configure the J9 jumper, located behind the power connector, for 12

V as shown below.

MAIN BOARD

24 VDC
12 VDC
POWER

J9

12 V

24 V

J9 CONFIGURATION

Factory
Default

M-LINK

+
_

Figure 4: Jumper Configuration for 12/24 VDC Power

Advertising
This manual is related to the following products: