7.3.14 Setting the Magnetic TOF

This setting is used to position the magnetic data at the correct distance from the leading edge of the
card. The Magnetic TOF is the distance from the edge of the card to the Start Sentinel (SS). The
Start Sentinel marks the beginning of the encoded data. According to the magnetic recording
standard (ISO 7811), the correct Start Sentinel distance is 0.293 inches ± 0.020 inches (7.44 mm ±
0.51 mm) from the leading edge of the card. To measure this distance, the data must be made visible
using a magnetic viewer or developer solution. Alternatively, use a magnetic card analyzer to
measure the Start Sentinel distance.

1. If using a magnetic viewer or developer solution or spray to make the magnetic data visible,

the Start Sentinel can be identified as the first set of magnetic lines (first one-bit) which are
visibly closer together than the large number of evenly spaced lines (leading zero-bits) that
fill the space to the edge of the card. See Figure 7-11. A magnifying device with a built-in
measuring scale makes this easier to measure.

2. Measure the distance from the edge of the card to the Start Sentinel in the data as seen in

Figure 7-11.

If the Start Sentinel is too far from the leading edge of the card, the Magnetic TOF
setting needs to be reduced (or made more negative).

If the Start Sentinel is too close to the leading edge of the card, the Magnetic TOF
setting needs to be increased (or made more positive).

3. Select MENU, Setup Printer, and Magnetic TOF.

4. Adjust the setting by the amount determined by the following formula:

(0.293 inches - measured SS distance (inches)) x 300 steps per in.,

or

(7.4 mm - measured SS distance (millimeter)) x 11.8 steps per mm.

Example: (

0.293 – 0.284) x 300 = 2.7

5. Press SELECT to save the value.

6. To test the position of the Start Sentinel, magnetically encode a card and check as described

in step 1.

7. Repeat steps 1 to 6 until the Magnetic TOF is correct.