Genicom 3850 User Manual

Page 103

Advertising
background image

99

Fixed Print Adjust

This method sets the gap and fine tunes it at the same time. This method is recommended
for forms of varying thickness such as shipping notices and envelopes. The range of the
fixed gap is from 0.3 to 8.6. A selection of 1.0 is the best for single part 20lbs. (75 g/m

2

). A

selection of 6.0 is the best lightweight 6-part forms. Higher selections should be used for
heavier or higher part count forms.

FORM: FIXED

ENTER

FORM:FIXED>0.6

or

This fixed gap value will be stored as a "path" parameter or as a "format" parameter based
upon the G

G

G

A

A

A

P

P

P

A

A

A

S

S

S

S

S

S

I

I

I

G

G

G

N

N

N

selection in the System Menu.

If GAP ASSIGN:PATH is selected in the System Menu, then the fixed gap value will be
stored for the currently selected path and will be recalled the next time paper is loaded in
the current path.

If GAP ASSIGN:FORMAT is selected in the System Menu, then the fixed gap value will be
stored in the current format. You must then save the current format to a numbered (1-4)
format. Then, the next time that particular format number is selected, the offset gap value
will be recalled.

Go back to the top level of the menu with the

PRIOR

key and press the

↓ key to select the

next menu item (EMULATION displays).

Advertising