Genicom 3850 User Manual

Page 145

Advertising
background image

141

Standard Functions

Automatic print head gap adjustment (AGA)

Automatic paper path switching via operator panel or S/W commands

Paper parking

Plug & Play capability

Bar Code printing

Automatic fanfold positioning for tear-off

Setting and storage of paper format and print conditions for each paper path in the non volatile memory

Physical and Electrical Characteristics

Interfaces

Parallel

Centronics Compatible Bi-directional (IEEE-1284) nibble and byte modes - 36 pin
Amphenol connector, 7/8 data bits

Receive Buffer: max. 32 Kbytes

Serial

RS-232/C and RS-422/A - dB 25 connector

Baud Rate: 300 to 38400 bps, 7/8 data bits, DTR & XonXoff flow

Receive Buffer: max. 32 Kbytes

Automatic interface switching

Reliability Requirements

MTBF

Mean Time between failure: 10000 hours at 25% DC

MTTR

Mean Time To Repair: 30 minutes

Workload

35,000 pages/month (ECMA 132 - 4 hours for 20 days)

Printer Life

5 years or 10000 hours @25%