3-35

BUS INTERFACE UNIT

Figure 3-31. Buffered AD Bus System

In a fully buffered system, DEN directly drives the transceiver output enable. A partially buffered
system requires that DEN be qualified with another signal to prevent the transceiver from going
active for local bus accesses. Figure 3-32 illustrates how to use chip-selects to qualify DEN.

DT/R always connects directly to the transceiver. However, an inverter may be required if the po-
larity of DT/R does not match the transceiver. DT/R goes low (0) only for memory and I/O read,
instruction prefetch and interrupt acknowledge bus cycles.

Latch

Processor

Data Bus

Address

Data

CS

CPU Local Bus

Buffered Bus

ALE

Memory

or

I/O

Device

A19:16

AD15:0

Address Bus

DT/ R

DEN

Transceiver

A1095-0A