Figure 95. timer 0 and timer 1 control registers – Intel 80C188XL User Manual

Page 237

Advertising
background image

TIMER/COUNTER UNIT

9-8

Figure 9-5. Timer 0 and Timer 1 Control Registers (Continued)

Register Name:

Timer 0 and 1 Control Registers

Register Mnemonic:

T0CON, T1CON

Register Function:

Defines Timer 0 and 1 operation.

Bit

Mnemonic

Bit Name

Reset

State

Function

RTG

Retrigger

X

This bit specifies the action caused by a low-to-high
transition on the TMR INx input. Set RTG to reset the
count; clear RTG to enable counting. This bit is
ignored with external clocking (EXT=1).

P

Prescaler

X

Set to increment the timer when Timer 2 reaches its
maximum count. Clear to increment the timer at ¼
CLKOUT. This bit is ignored with external clocking
(EXT=1).

EXT

External
Clock

X

Set to use external clock; clear to use internal clock.
The RTG and P bits are ignored with external clocking
(EXT set).

ALT

Alternate
Compare
Register

X

This bit controls whether the timer runs in single or
dual maximum count mode (see Figure 9-4 on page
9-6)
. Set to specify dual maximum count mode; clear
to specify single maximum count mode.

CONT

Continuous
Mode

X

Set to cause the timer to run continuously. Clear to
disable the counter (clear the EN bit) after each
counting sequence.

NOTE:

Reserved register bits are shown with gray shading. Reserved bits must be written to a
logic zero to ensure compatibility with future Intel products.

15

0

C
O
N

T

A

L
T

E
X
T

R

T

G

M

C

P

R

I

U

I

N

T

I

N
H

E
N

A1297-0A