8-23

INTERRUPT CONTROL UNIT

Figure 8-14. Interrupt Status Register

NOTE

Do not write to the DHLT bit while Timer/Counter Unit interrupts are enabled.
A conflict with the internal use of the register may cause incorrect processing
of timer interrupts.

The DHLT bit does not function when the interrupt controller is in slave mode.

8.5

SLAVE MODE

Although Master mode is the most common, Slave mode is useful in larger system designs. In
Slave mode, an external 8259A module controls the interrupt input to the CPU and acts as the
master interrupt controller. The Interrupt Control Unit processes only the internal interrupt re-
quests and acts as an interrupt input to the external 8259A. In simplest terms, the Interrupt Control
Unit behaves like a cascaded 8259A to the master 8259A. (See Figures 8-15 and 8-16.)

Register Name:

Interrupt Status Register

Register Mnemonic:

INTSTS

Register Function:

Indicates pending shared-source interrupts and
DMA suspension

Bit

Mnemonic

Bit Name

Reset

State

Function

DHLT

DMA Halt

0

This bit is set to suspend DMA activity.

TMR2:0

Timer
Interrupt
Pending

000

A bit is set to indicate a pending interrupt from
the corresponding timer.

NOTE:

Reserved register bits are shown with gray shading. Reserved bits must be written
to a logic zero to ensure compatibility with future Intel products.