Figure 95. timer 0 and timer 1 control registers, Figure 9-5 an – Intel 80C188XL User Manual

Page 236

Advertising
background image

9-7

TIMER/COUNTER UNIT

Figure 9-5. Timer 0 and Timer 1 Control Registers

Register Name:

Timer 0 and 1 Control Registers

Register Mnemonic:

T0CON, T1CON

Register Function:

Defines Timer 0 and 1 operation.

Bit

Mnemonic

Bit Name

Reset

State

Function

EN

Enable

0

Set to enable the timer. This bit can be written only
when the INH bit is set.

INH

Inhibit

X

Set to enable writes to the EN bit. Clear to ignore
writes to the EN bit. The INH bit is not stored; it
always reads as zero.

INT

Interrupt

X

Set to generate an interrupt request when the Count
register equals a Maximum Count register. Clear to
disable interrupt requests.

RIU

Register In
Use

X

Indicates which compare register is in use. When set,
the current compare register is Maxcount Compare B;
when clear, it is Maxcount Compare A.

MC

Maximum
Count

X

This bit is set when the counter reaches a maximum
count.

The MC bit must be cleared by writing to the

Timer Control register. This is not done automati-
cally.
If MC is clear, the counter has not reached a
maximum count.

NOTE:

Reserved register bits are shown with gray shading. Reserved bits must be written to a
logic zero to ensure compatibility with future Intel products.

15

0

C
O
N

T

A

L
T

E
X
T

R

T

G

M

C

P

R

I

U

I

N

T

I

N
H

E
N

A1297-0A