Lift – Juniper Networks MX480 User Manual

Page 100

Advertising
background image

Tools Required to Install the MX480 Router with a Mechanical Lift on page 69

Removing Components from the MX480 Router Before Installing It with a Lift on
page 69

Reinstalling Components in the MX480 Router After Installing It with a Lift on page 76

Reinstalling Components in the MX480 Router After Installing It with a Lift

After the router is installed in the rack, you reinstall the removed components before
booting and configuring the router. The following procedures describe how to reinstall
components in the chassis, first in the rear and then in the front:

1.

Reinstalling the Power Supplies After Installing the MX480 Router with a
Lift on page 76

2.

Reinstalling the Fan Tray After Installing the MX480 Router with a Lift on page 77

3.

Reinstalling the SCBs After Installing the MX480 Router with a Lift on page 78

4.

Reinstalling the DPCs After Installing the MX480 Router with a Lift on page 79

5.

Reinstalling the FPCs After Installing the MX480 Router with a Lift on page 80

Reinstalling the Power Supplies After Installing the MX480 Router with a Lift

Reinstall the rightmost power supply first and then work your way to the left. To reinstall
the AC or DC power supplies, follow this procedure for each power supply (see

Figure 42

on page 77

, which shows the installation of the DC power supplies):

1.

Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect
the strap to one of the ESD points on the chassis.

2.

On an AC-powered router, switch the AC input switch on each power supply to the
off (

O

) position. On a DC-powered router, Move the DC circuit breaker on each DC

power supply to the off (

O

) position.

We recommend this even though the power supplies are not connected to power
sources.

3.

Using both hands, slide the power supply straight into the chassis until the power
supply is fully seated in the chassis slot. The power supply faceplate should be flush
with any adjacent power supply faceplate or blank installed in the power supply slot.

4.

Tighten the captive screws.