Mx480 as msc leds, Table 4: as msc leds – Juniper Networks MX480 User Manual

Page 48

Advertising
background image

Related

Documentation

MX480 AS MSC LEDs on page 24

Replacing an MX480 AS MSC on page 217

MX480 AS MSC LEDs

Two LEDs (

CPU

and

AP

) indicate the status of the AS MSC and are located on the AS

MSC.

Table 4 on page 24

describes the functions of the AS MSC LEDs.

Table 4: AS MSC LEDs

Description

State

Color

Label

AS MSC operates normally.

On steadily

Green

CPU

AS MSC has an error or has failed.

On steadily

Red

AS MSC is offline.

Off

AS MSC storage operation is normal.

On steadily

Green

AP

AS MSC storage operation has an error.

On steadily

Red

AS MSC storage operation is not activated.

Off

Related

Documentation

MX480 Application Services Modular Storage Card Description on page 23

Replacing an MX480 AS MSC on page 217

MX480 Application Services Modular Processing Card Overview

MX480 Application Services Modular Processing Card Description on page 24

MX480 AS MXC LEDs on page 25

MX480 Application Services Modular Processing Card Description

The Application Services Modular Processing Card (AS MXC) is a pluggable X86-based
card that can be inserted into the lower slot of the Application Services Modular Line
Card (AS MLC). The AS MXC serves as the processing card for the Junos Content Encore
system and contains the two X86, Intel 8-core processors with interface ability greater
than 80 Gbps. The AS MXC (see

Figure 13 on page 25

) is equivalent to a PIC or MIC

(Modular Interface Card).

AS MXCs are hot-removable and hot-insertable. One MXC can be installed in the lower
slot of each AS MLC. Each MXC has these components:

Two 8-core Intel processors—Contains eight execution cores with Ring Interconnect
architecture. Each core supports two threads, up to 16 threads per socket.

64 GB DRAM—On DIMM sockets.

Copyright © 2013, Juniper Networks, Inc.

24

MX480 3D Universal Edge Router Hardware Guide