Dc power cable specifications for the mx480 router, Figure 132: dc power cable lug, Table 43: dc power cable specifications – Juniper Networks MX480 User Manual

Page 328

Advertising
background image

WARNING:

For field-wiring connections, use copper conductors only.

CAUTION:

Power cords and cables must not block access to device

components or drape where people could trip on them.

Related

Documentation

In Case of an Electrical Accident on page 268

MX480 DC Power Supply Description on page 44

Connecting Power to a DC-Powered MX480 Router with Normal Capacity Power
Supplies on page 108

Replacing an MX480 DC Power Supply Cable on page 236

DC Power Cable Specifications for the MX480 Router

DC Power Cable Lug Specifications—The accessory box shipped with the router includes
the cable lugs that attach to the terminal studs of each power supply (see

Figure 132 on

page 304

).

Figure 132: DC Power Cable Lug

CAUTION:

Before router installation begins, a licensed electrician must attach

a cable lug to the grounding and power cables that you supply. A cable with
an incorrectly attached lug can damage the router.

NOTE:

The same cable lug is used for the grounding cable.

DC Power Cable Specifications—

Table 43 on page 304

summarizes the specifications for

the power cables, which you must supply.

Table 43: DC Power Cable Specifications

Quantity and Specification

Cable Type

Eight 6-AWG (13.3 mm

2

), minimum 60°C wire, or as required by the local

code

Power

Copyright © 2013, Juniper Networks, Inc.

304

MX480 3D Universal Edge Router Hardware Guide

Advertising