Figure 104: installing an mpc, Ok master, Online offline – Juniper Networks MX480 User Manual

Page 231: Aco/lt yellow alarm red alarm nc no c nc no c, Reo re1, Issue the following cli command

Advertising
background image

CAUTION:

Avoid bending fiber-optic cable beyond its minimum bend

radius. An arc smaller than a few inches in diameter can damage the cable
and cause problems that are difficult to diagnose.

13.

Use one of the following methods to bring the MPC online:

•

Press and hold the corresponding MPC online button on the craft interface until the
green

OK/FAIL

LED next to the button lights steadily, in about 5 seconds.

•

Issue the following CLI command:

user@host>

request chassis fpc slot slot-number online

For more information about the command, see the Junos OS Operational Mode
Commands.

CAUTION:

After the

OK/FAIL

LED lights steadily, wait at least 30 seconds

before removing the MPC again, removing an MPC from a different slot,
or inserting an MPC in a different slot.

You can also verify correct MPC and MIC functioning by issuing the

show chassis fpc

and

show chassis fpc pic-status

commands described in

“Maintaining MX480 MPCs” on

page 135

and

“Maintaining MX480 MICs” on page 137

.

Figure 104: Installing an MPC

OK

MASTER

FAN

ONLINE

OFFLINE

0

1

1

0

FAIL

FAIL

PEM

FAIL

FAIL

FAIL

FAIL

FAIL

FAIL

ESD

OK

OK

OK

OK

OK

OK

OK

2

3

4

5

ACO/LT

YELLOW ALARM

RED ALARM

NC

NO

C

NC

NO

C

MX480

REO

RE1

0 1 2 3

SCB

SCB

g004912

Related

Documentation

MX480 Modular Port Concentrator (MPC) Description on page 13

•

•

Maintaining MX480 MPCs on page 135

•

Tools and Parts Required to Replace MX480 Hardware Components on page 162

•

Replacing an MX480 MIC on page 208

•

Preventing Electrostatic Discharge Damage to an MX480 Router on page 248

•

MX480 MPC Serial Number Label on page 322

207

Copyright © 2013, Juniper Networks, Inc.

Chapter 14: Replacing MX480 Hardware Components

Advertising