Installing an mx480 mic, Figure 107: installing the septum – Juniper Networks MX480 User Manual

Page 234

Advertising
background image

Installing an MX480 MIC

To install a MIC (see

Figure 108 on page 211

):

1.

Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect
the strap to one of the ESD points on the chassis.

2.

If you have used a dual-wide MIC and are now replacing it with two “single” MICs,
install the septum (see

Figure 107 on page 210

):

a.

Place the MPC on a flat surface (If necessary, remove the MPC from the router as
described in

“Removing an MX480 MPC” on page 204

).

b.

Position the septum in the center of the MPC so that it lines up with holes labeled

S

on the top of the MPC.

c.

Insert a screw into each of the two holes labeled

S

, and then tighten completely.

d.

On the bottom of the MPC, insert a screw into each of the four holes labeled

S

, and

then tighten completely.

e.

Install the MPC as described in

“Installing an MX480 MPC” on page 206

.

Figure 107: Installing the Septum

g005041

Install four screws
on bottom.

Slide septum
into MPC.
Install two
screws.

3.

If the MIC uses fiber-optic cable, verify that a rubber safety cap is over each transceiver
on the faceplate. Install a cap if necessary.

4.

On the MPC, pull the ejector lever that is adjacent to the MIC you are installing away
from the MPC faceplate.

5.

Align the rear of the MIC with the guides located at the corners of the MIC slot.

6.

Slide the MIC into the MPC until it is firmly seated in the MPC.

CAUTION:

Slide the MIC straight into the slot to avoid damaging the

components on the MIC.

7.

Verify that the ejector lever is engaged by pushing it toward the MPC faceplate.

8.

If the MIC uses fiber-optic cable, remove the rubber safety cap from each transceiver
and the end of each cable.

Copyright © 2013, Juniper Networks, Inc.

210

MX480 3D Universal Edge Router Hardware Guide

Advertising