CHAPTER 6

Installing the MX480 Router Mounting
Hardware

Installing the MX480 Router Mounting Hardware for a Rack or Cabinet on page 65

Moving the Mounting Brackets for Center-Mounting the MX480 Router on page 67

Installing the MX480 Router Mounting Hardware for a Rack or Cabinet

The router can be installed in a four-post rack or cabinet or an open-frame rack. Install
the mounting hardware on the rack before installing the router.

Install the mounting shelf, which is included in the shipping container, before installing
the router. We recommend that you install the mounting shelf because the weight of a
fully loaded chassis can be up to 163.5 lb (74.2 kg).

Table 23 on page 65

specifies the holes in which you insert cage nuts and screws to install

the mounting hardware required (an

X

indicates a mounting hole location). The hole

distances are relative to one of the standard U divisions on the rack. The bottom of all
mounting shelves is at 0.02 in. above a U division.

Table 23: Four-Post Rack or Cabinet Mounting Hole Locations

Mounting Shelf

Distance Above U Division

Hole

X

1.14 U

2.00 in. (5.1 cm)

4

X

0.86 U

1.51 in. (3.8 cm)

3

X

0.50 U

0.88 in. (2.2 cm)

2

X

0.14 U

0.25 in. (0.6 cm)

1

To install the mounting shelf on the front rails of a four-post rack or cabinet, or the rails
of an open-frame rack:

1.

If needed, install cage nuts in the holes specified in

Table 23 on page 65

.

2.

On the back of each rack rail, partially insert a mounting screw into the lowest hole
specified in

Table 23 on page 65

.

65

Copyright © 2013, Juniper Networks, Inc.