Scb slots, Scb redundancy, Scb components – Juniper Networks MX480 User Manual

Page 51: 27 scb redundancy, 27 scb components, Figure 14: scb

Advertising
background image

Monitors and controls system functions, including fan speed, board power status, PDM
status and control, and the craft interface

Provides interconnections to all the DPCs, FPCs, and MPCs within the chassis through
the switch fabrics integrated into the SCB

The Routing Engine installs directly into a slot on the SCB (see

Figure 14 on page 27

).

Figure 14: SCB

SCB Slots

You can install one or two. The SCBs install horizontally into the front of the chassis in
the slots labeled

0

and

1

. If any slots are empty, you must install a blank panel.

SCB Redundancy

If two SCBs are installed, one SCB functions as the master SCB and the other as its
backup. If the master fails or is removed, the backup restarts and becomes the master.

SCB Components

Each SCB consists of the following components:

Chassis management Ethernet switch

I2C bus logic, used for low-level communication with each component

Component redundancy circuitry

Control Board/Routing Engine mastership mechanism

Gigabit Ethernet switch that is connected to the embedded CPU complex on all
components

27

Copyright © 2013, Juniper Networks, Inc.

Chapter 2: MX480 Hardware Components