Juniper Networks MX480 User Manual

Page 207

Advertising
background image

FPC 1
PFE #0
Plane 0: Links ok
Plane 1: Links ok
Plane 2: Plane enabled
Plane 3: Plane enabled
Plane 4: Plane enabled
Plane 5: Plane enabled
PFE #1
Plane 0: Links ok
Plane 1: Links ok
Plane 2: Plane enabled
Plane 3: Plane enabled
Plane 4: Plane enabled
Plane 5: Plane enabled
PFE #2
Plane 0: Links ok
Plane 1: Links ok
Plane 2: Plane enabled
Plane 3: Plane enabled
Plane 4: Plane enabled
Plane 5: Plane enabled
PFE #3
Plane 0: Links ok
Plane 1: Links ok
Plane 2: Plane enabled
Plane 3: Plane enabled
Plane 4: Plane enabled
Plane 5: Plane enabled

Fabric plane details of all MPCs are similarly displayed.

7.

Verify if any output of the show chassis fabric summary command shows fabric
planes in 'check' state, as it indicates that the fabric plane has an error. You can try
to recover the fabric plane to normal operation by issuing the request chassis fabric
plane <#> offline command, followed by the request chassis fabric plane <#> online
command, where <#> equals the fabric plane in error.

NOTE:

After you issue the request chassis fabric plane <#> offline and

request chassis fabric plane <#> online commands, issue the show
chassis fabric summary command to verify that the fabric plane errors
are rectified and to verify the current state of the fabric planes.

8.

Verify that the major alarms are displayed by issuing the

show chassis alarms

command:

user@host>

show chassis alarms

Alarm Time Class Description
2011-06-01 13:37:43 EDT Minor Require a fan tray upgrade
2011-06-01 13:37:26 EDT Minor Backup RE Active

The major alarms are not displayed anymore, and the upgrade is successfully
completed.

9.

Disable the upgrade configuration by issuing the

set chassis state cb-upgrade off

command and then the

commit

command.

183

Copyright © 2013, Juniper Networks, Inc.

Chapter 14: Replacing MX480 Hardware Components