Replacing an MX480 AC Power Supply

1.

Removing an MX480 AC Power Supply on page 228

2.

Installing an MX480 AC Power Supply on page 229

Removing an MX480 AC Power Supply

Before you remove a power supply, be aware of the following:

NOTE:

The minimum number of power supplies must be present in the router

at all times.

CAUTION:

To maintain proper cooling and prevent thermal shutdown of the

operating power supply unit, each power supply slot must contain either a
power supply or a blank panel. If you remove a power supply, you must install
a replacement power supply or a blank panel shortly after the removal.

NOTE:

After powering off a power supply, wait at least 60 seconds before

turning it back on.

To remove an AC power supply (see

Figure 118 on page 229

):

1.

Switch off the dedicated customer site circuit breaker for the power supply, and
remove the power cord from the AC power source. Follow the instructions for your
site.

2.

Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect
the strap to one of the ESD points on the chassis.

3.

Move the AC input switch next to the appliance inlet on the power supply to the off

(

O

) position.

4.

Remove the power cord from the power supply.

5.

Unscrew the captive screws on the bottom edge of the power supply.

6.

Pull the power supply straight out of the chassis.