Maintaining the mx480 power supplies, Figure 78: do not stack fpcs – Juniper Networks MX480 User Manual

Page 171

Advertising
background image

CAUTION:

To prevent damage when storing FPCs:

Never lay an FPC component-side down.

•

Figure 78: Do Not Stack FPCs

•

Never stack an FPC under or on top of any other component (see

Figure

78 on page 147

).

Related

Documentation

MX480 Flexible PIC Concentrator (FPC) Description on page 16

•

•

MX480 FPC Terminology on page 143

•

Holding an MX480 FPC on page 144

Maintaining the MX480 Power Supplies

Purpose

For optimum router performance, verify the condition of the power supplies.

Action

On a regular basis:

•

Check the status of the power supplies by issuing the

show chassis environment pem

command. The output is similar to the following:

user@host>

show chassis environment pem

PEM 0 status:
State Online
Temperature OK
AC Input: OK
DC Output Voltage(V) Current(A) Power(W) Load(%)
59 0 0 0
PEM 1 status:
State Online
Temperature OK
AC Input: OK
DC Output Voltage(V) Current(A) Power(W) Load(%)
59 18 1062 42

•

Make sure that the power and grounding cables are arranged so that they do not
obstruct access to other router components.

147

Copyright © 2013, Juniper Networks, Inc.

Chapter 12: Maintaining MX480 Router Hardware Components

Advertising