Table 36: fru power requirements – Juniper Networks MX480 User Manual

Page 314

Advertising
background image

NOTE:

The power for the cooling system comes from a different tap on the

power supply, reserved for the cooling system only. The cooling system power
requirement does not need to be deducted from the output power budget
of the power supply.

Table 36: FRU Power Requirements

Maximum Power Requirement

Part Number

Component

Switch Control Boards (SCBs)

150 W

SCB-MX960 (applies to
MX240, MX480, and
MX960)

Switch Control Board

150 W

SCBE-MX (applies to
MX240, MX480, and
MX960)

Enhanced MX Switch
Control Board

Routing Engines

90 W

RE-S-1300-2048

RE-S-1800X2-8G

RE-S-1800X4-8G

RE-S-1800X2-16G

RE-S-1800X4-16G

RE-S-2000-4096

Routing Engines

MPCs

440 W at 55 degrees C ambient

423 W at 25 degrees C ambient

MPC-3D-16XGE-SFPP

MPC-3D-16XGE-SFPP-R-B

16x10GE MPC

165 W

With MICs and optics:

239 W at 55 degrees C

227 W at 40 degrees C

219 W at 25 degrees C

MX-MPC1-3D

MX-MPC1E-3D

MPC1

175 W

With MICs and optics:

249 W at 55 degrees C

237 W at 40 degrees C

228 W at 25 degrees C

MX-MPC1-3D-Q

MX-MPC1E-3D-Q

MPC1 Q