Table 29: mx480 dc zoning – Juniper Networks MX480 User Manual

Page 310

Advertising
background image

Both normal-capacity and high-capacity MX480 chassis with DC power supplies are
zoned, meaning that certain components are powered by specific power supplies (see

Table 29 on page 286

for information on zoning). When calculating power requirements,

be sure that there is adequate power for each zone.

For an AC-powered chassis, there is one overall zone. Two AC power supplies are
mandatory for high-line, and three AC power supplies are mandatory for low-line power.

Table 29: MX480 DC Zoning

Components Receiving Power

Power Supply (PEM)

Zone

PEM 0 or 2

Zone 0

Fan Tray

DPC/MPC slots 0 and 1

SCB slots 0 and 1

PEM 1 or 3

Zone 1

Fan Tray

DPC slots 2 through 5

The following sample configuration shows a DC-powered MX480 with:

Two 16-port 10-Gigabit Ethernet MPCs with SFP+(slots 0 and 1)

Two SCBs with two (redundant) RE-1800x2 routing engines (SCB slot 0 and SCB slot
1)

One DPCE-R-4XGE-XFP (slot 3)

High-capacity cooling system

NOTE:

The high-capacity cooling system satisfies cooling requirements

of MPCs, and must be used for proper cooling.

Copyright © 2013, Juniper Networks, Inc.

286

MX480 3D Universal Edge Router Hardware Guide

Advertising