Troubleshooting the mx480 pics – Juniper Networks MX480 User Manual

Page 179

Advertising
background image

Temperature 24 degrees C / 75 degrees F
Total CPU DRAM 1024 MB
Total RLDRAM 128 MB
Total DDR DRAM 2048 MB
Start time: 2008-12-11 16:53:24 PST
Uptime: 15 hours, 2 minutes, 47 seconds
Max Power Consumption 368 Watts
Slot 2 information:
State Online
Temperature 29 degrees C / 84 degrees F
Total CPU DRAM 1024 MB
Total RLDRAM 256 MB
Total DDR DRAM 4096 MB
Start time: 2008-12-11 16:53:18 PST
Uptime: 15 hours, 2 minutes, 53 seconds
Max Power Consumption 294 Watts
Slot 3 information:
State Online
Temperature 29 degrees C / 84 degrees F
Total CPU DRAM 1024 MB
Total RLDRAM 256 MB
Total DDR DRAM 4096 MB
Start time: 2008-12-11 16:53:18 PST
Uptime: 15 hours, 2 minutes, 53 seconds
Max Power Consumption 335 Watts
Slot 4 information:
State Online
Temperature 29 degrees C / 84 degrees F
Total CPU DRAM 1024 MB
Total RLDRAM 256 MB
Total DDR DRAM 4096 MB
Start time: 2008-12-11 16:53:18 PST
Uptime: 15 hours, 2 minutes, 53 seconds
Max Power Consumption 333 Watts

For further description of the output from the commands, see the Junos OS System
Basics Configuration Guide.

Related

Documentation

MX480 Flexible PIC Concentrator (FPC) LEDs on page 18

Replacing an MX480 FPC on page 194

Holding an MX480 FPC on page 144

Storing an MX480 FPC on page 146

Maintaining MX480 FPCs on page 132

Troubleshooting the MX480 PICs

Problem

The PICs are not functioning normally.

Solution

Check the status of each port on a PIC by looking at the LED located on the PIC
faceplate. For information about the meaning of LED states on different PICs, see the

MX Series 3D Universal Edge Routers Line Card Guide

.

Check the status of a PIC by issuing the

show chassis fpc pic-status

CLI command. The

PIC slots in the FPC are numbered from

0

through

1

, left to right:

155

Copyright © 2013, Juniper Networks, Inc.

Chapter 13: Troubleshooting MX480 Hardware Components

Advertising