Scb leds on the mx480 craft interface, Fan leds on the mx480 craft interface, Alarm relay contacts on the mx480 craft interface – Juniper Networks MX480 User Manual

Page 64: 40 fan leds on the mx480 craft interface, Table 15: scb leds on the craft interface, 40 table 16: fan leds on the craft interface

Advertising
background image

SCB LEDs on the MX480 Craft Interface

Each SCB has two LEDs on the craft interface that indicates its status. The SCB LEDs,
labeled

0

and

1

, are located along the bottom of the craft interface.

Table 15 on page 40

describes the functions of the SCB LEDs.

Table 15: SCB LEDs on the Craft Interface

Description

State

Color

Label

SCB: Fabric and control board functioning normally.

On steadily

Green

OK

SCB is transitioning online or offline.

Blinking

The slot is not online.

Off

SCB has failed.

On steadily

Red

FAIL

Fan LEDs on the MX480 Craft Interface

The fan LEDs are located on the top left of the craft interface.

Table 16 on page 40

describes the functions of the fan LEDs.

Table 16: Fan LEDs on the Craft Interface

Description

State

Color

Label

Fan is functioning normally.

On steadily

Green

FAN

Fan has failed.

On steadily

Red

Related

Documentation

MX480 Craft Interface Description on page 37

Alarm LEDs and Alarm Cutoff/Lamp Test Button on the MX480 Craft Interface on
page 37

Alarm Relay Contacts on the MX480 Craft Interface on page 40

Alarm Relay Contacts on the MX480 Craft Interface

The craft interface has two alarm relay contacts for connecting the router to external
alarm devices (see

Figure 20 on page 41

). Whenever a system condition triggers either

the red or yellow alarm on the craft interface, the alarm relay contacts are also activated.
The alarm relay contacts are located on the upper right of the craft interface.

Copyright © 2013, Juniper Networks, Inc.

40

MX480 3D Universal Edge Router Hardware Guide

Advertising