Kawasaki D Series Controller MPVDCONTV113E-3 User Manual

Page 109

Advertising
background image

TROUBLESHOOTING

D SERIES CONTROLLER

TROUBLESHOOTING AND COMPONENT REPLACEMENT

1-106

August 9, 2005

Ka a a

w s k

ERROR CODE E1130

Jt XX collision was detected.

Motor current command value exceeds the threshold value set in AUX 0510.

⇒

Remove obstacles in the robot motion path area.

⇒

Ensure tool settings are correct.

⇒

If an obstacle was not encountered, increase the threshold value set in AUX 0510.

_____________________________________________________________________

ERROR CODE E1131

Jt XX Unexpected shock is detected.

Change in motor current command value, per unit of time, exceeds the threshold value
set in AUX 0510.

⇒

Remove obstacles in the robot motion path area.

⇒

Ensure tool settings are correct.

⇒

If an obstacle was not encountered, increase the threshold value set in AUX 0510.

_____________________________________________________________________

ERROR CODE E1132

Motor power OFF. Measurement stopped.

This error occurs when motor power is interrupted during auto load measurement.

Main causes include:
1. External HOLD/RUN switch is set to HOLD.
2. TEACH/REPEAT switch is set to TEACH.
3. External EMERGENCY STOP switch is pressed.

⇒

Reset switches to allow repeat operation. Repeat the auto load measurement.

⇒

Ensure the motor power is not interrupted during auto load measurement. Repeat
the auto load measurement.

_____________________________________________________________________

ERROR CODE E1133

Conveyor has reached max. value position.

The conveyor exceeded the maximum value set for the conveyor during program execu-
tion.

⇒

Ensure conveyor maximum value is set correctly.

⇒

Modify program data as necessary.

_____________________________________________________________________