Kawasaki D Series Controller MPVDCONTV113E-3 User Manual

Page 205

Advertising
background image

TROUBLESHOOTING

D SERIES CONTROLLER

TROUBLESHOOTING AND COMPONENT REPLACEMENT

1-202

August 9, 2005

Ka a a

w s k

ERROR CODE W1010

RAM battery low voltage.

Main causes include:
1. Backup battery voltage below minimum value (3.3 VDC or less).
2. Defective battery harness.
3. Defective 1KA board.

⇒

Back up system and program data. Check and replace batteries as required.

⇒

Check batteries for defective connections. Repair as required.

⇒

Defective battery voltage monitoring circuit. Replace the 1KA board.

_____________________________________________________________________

ERROR CODE W1011

PLC alarm. (XX)

This error occurs when a PC3JB (TOYOPUC) internal error (alarm) is present (battery
voltage low error, etc.).

⇒

Refer to the PC3JB (TOYOPUC) manual for the alarm code (XX).

⇒

Replace the PC3JB (TOYOPUC).

_____________________________________________________________________

ERROR CODE W1012

Servo parameter Changed. Turn OFF & ON the control
power.

When robot model, number of axes, servo parameters for external axes, or the 1KB
board are changed, controller power must be cycled OFF and ON.

⇒

When model is changed, the servo software must also be changed.

⇒

Cycle controller power OFF and ON.

_____________________________________________________________________

Advertising