ERROR CODE P1034

This program is not editable.

The auto load measurement program cannot be edited.

⇒

Use a program name that does not include the auto load measurement program
name.

_____________________________________________________________________

ERROR CODE P1035

Record inhibited. Set [record accept] and operate again.

Displayed when an attempt is made to enter data, but Inhibit Record in auxiliary function
0802 is set to inhibit.

⇒

Change the setting of the Inhibit Record in AUX 0802.

_____________________________________________________________________

ERROR CODE P1036

Program change inhibited. Set [Accept] and operate
again.

Displayed when an attempt is made to enter data, but Program Change in auxiliary
function 0802 is set to inhibit.

⇒

Change the setting of the Program Change in AUX 0802.

_____________________________________________________________________

ERROR CODE P1037

Program name cannot be called “calib_load_”.

⇒

Use a program name that does not include

“calib_load_

“.

_____________________________________________________________________

ERROR CODE P1038

Program does not exist.

Main causes include:
1. Non-existing program is selected.
2. Program check operation or cycle start is executed without a program selected.

⇒

Select an existing program before executing program check or cycle start.

_____________________________________________________________________