TROUBLESHOOTING

D SERIES CONTROLLER

TROUBLESHOOTING AND COMPONENT REPLACEMENT

1-92

August 9, 2005

Ka a a

w s k

ERROR CODE E1076

Cannot use negative time value.

Displayed when a negative number is entered as part of a DELAY or TIMER command.

⇒

Correct the time setting to a positive number.

_____________________________________________________________________

ERROR CODE E1077

No value set.

Occurs when an instruction like the BITS command is evaluated and there is no corre-
sponding value set.

⇒

Correct program code to evaluate existing values.

_____________________________________________________________________

ERROR CODE E1078

Illegal signal number.

This error is displayed when the RUNMASK, SIGNAL, BITS, PULSE, or SWAIT com-
mands are used with a signal number that exceeds the range permitted by system
configuration.

⇒

Check signal number specified in the instruction and ensure it is within system con-
figuration.

_____________________________________________________________________

ERROR CODE E1079

Cannot use dedicated signal.

Occurs when a previously dedicated signal is used as a general purpose signal.

⇒

Use signals that have not been dedicated for specific functions.

_____________________________________________________________________

ERROR CODE E1080

Not RPS mode.

Main causes include:
1. External program reset signal is received, but RPS ON signal, or external program

input signal is not dedicated.

2. JUMP is taught in a block step program, but external program input signal is not

dedicated.

3. END is taught in a block step program, but the RPS ON signal is not dedicated.
4. EXTCALL is executed, but the signal for external program input is not dedicated.

⇒

Correct the program data.

⇒

If RPS is to be used the necessary signals must be dedicated.

_____________________________________________________________________