TROUBLESHOOTING

D SERIES CONTROLLER

TROUBLESHOOTING AND COMPONENT REPLACEMENT

1-192

August 9, 2005

Ka a a

w s k

ERROR CODE P2059

[SerialFlash] data write error.

The specified file cannot be written to the 1KA board.

Main causes include:
1. The file is corrupt.
2. The serial flash memory on the 1KA board is set to write-protect.

⇒

Ensure the 1KA board serial flash memory is not set to write-protect

.

⇒

Replace the 1KA board serial flash memory.

_____________________________________________________________________

ERROR CODE P2060

[SerialFlash] File or directory doesn’t exist.

The specified file or directory does not exist in the serial flash memory on the 1KA
board.

⇒

Ensure the file or directory exists in the serial flash memory

.

⇒

Create a new file or directory.

_____________________________________________________________________

ERROR CODE P2061

File does not exist in floppy.

When accessing the floppy disk, the specified file cannot be found on the floppy disk.

⇒

Ensure an existing file name is specified

.

_____________________________________________________________________

ERROR CODE P2062

[FDD/PC_CARD] Failure in writing data per verify function.

When the verify function is enabled in AUX 0208, the destination and source data are
compared when writing data to a floppy disk or PC card. This error occurs if the data
does not match.

⇒

Replace the floppy disk/PC card.

⇒

If this error recurs, replace the 1KA/1KF boards or harness.

_____________________________________________________________________

ERROR CODE P2063

[FDD/PC_CARD] Faulty response from verify function.

Setting enable or disable for the verify function in AUX 0208 failed.

⇒

Re-execute

.

⇒

If this error recurs, replace the 1KF board.

_____________________________________________________________________